Dry Heat Sterilizer

Product Details:
- Material SS 304
- Computerized No
- Voltage 380 Volt (v)
- Power 220 Volt (v)
- Weight (kg) 200-500 Kilograms (kg)
- Dimension (L*W*H) 1200 X 900 X 1070 Millimeter (mm)
- Color Sliver
Dry Heat Sterilizer Price And Quantity
- 300000 INR
- 1 Unit
Dry Heat Sterilizer Product Specifications
- Sliver
- 380 Volt (v)
- SS 304
- 1200 X 900 X 1070 Millimeter (mm)
- 200-500 Kilograms (kg)
- No
- 1 Year
- 220 Volt (v)
Dry Heat Sterilizer Trade Information
- Nhava Sheva
- Letter of Credit (L/C) Telegraphic Transfer (T/T) Cash in Advance (CID) Cash Advance (CA)
- 4 Unit Per Month
- 4 Week
- Wooden Box.
- Western Europe Australia North America Eastern Europe Middle East South America Asia Central America Africa
- All India
Product Description
We are one of the prominent entity, engrossed in manufacturing and supplying an extensive array of Dry Heat Sterilizer. Manufactured with the help of ultra-modern technique and quality approved components, this sterilizer is duly tested as per the set industry standards. This sterilizer is suitable for sterilize washed ampoules, vials and other cylindrical containers of glass. Further, we offer this Dry Heat Sterilizer in various specifications and at market leading prices.
Features:
Trouble free operation
Negligible functioning
Energy efficient
Sturdy construction
Complete GMP model.
Basic structure made from M.S. Heavy angles.
Sterilizer inner walls made from AISI SS 316 and outer walls made from AISI SS 304.
Doors provided on both sides, one opening is in non-sterile area and second opening in sterile area.
"grade mineral wool insulation to optimize heat effectiveness and stop heat loses.
Dynamically balanced fan provided for hot air circulation to achieve uniform temperature.
Complete electric panel board with pulley and damper connection.
Process Operation
Heating Cycle
The Ampoules / Vials placed in trays are washed in non-sterile room and loaded on the trolley.
The trolley is moved to the sterilizer on a transfer trolley. Temperature and Times are set on the Digital Controller. The Impeller mounted on the top circulates the hot air horizontally over the charge. The air is heated by elements mounted on the top. Fresh air enters the system through Hepa Filter Module. The system incorporates two doors, one opening into the sterile room and the other opening in the non-sterile room. Both the doors are pneumatically interlocked. The temperature profile during sterilization cycle is recorded on a circular chart recorder, validation of the system is provided by a six-point digital temperature scanner.
Cooling Cycle
After the time period required for sterilizing the batch has elapsed, the heating circuit shuts of the
pneumatics damper (exhaust) opens and cooling operation commences.